MixRite Water-Driven Dosing Pump

Availability: In stock
Only %1 left
Missing Image

Currently, there are no specifications available for this product.

Empty Title Price Quantity In Cart
WMR049
MixRite Water-Driven Dosing Pump - 0.03% to 0.9% (3333:1 - 500:1 ) Dosage Rate - 0.5 to 14 GPM - 3/4-Inch MPT
$892.25
MSRP: $1,070.70
Margin: 20%

Qty: 4

Commerce, CA: 4

Sacramento, CA: 0

0
STK

PRODUCT IN STOCK

WMR050
MixRite Water-Driven Dosing Pump - 0.3% to 2% (333:1 - 50:1) Dosage Rate- 0.5 to 14 GPM - 3/4-Inch MPT
$528.37
MSRP: $634.05
Margin: 20%

Qty: 1

Commerce, CA: 1

Sacramento, CA: 0

0
STK

PRODUCT IN STOCK

WMR060
MixRite Water-Driven Dosing Pump - 0.1% to 0.9% (1000:1 - 111:1) Dosage Rate - 0.5 to 14 GPM - 3/4-Inch MPT
$528.37
MSRP: $634.05
Margin: 20%

Qty: 0
0
O
OUT OF STOCK
WMR007
MixRite TF5 Water-Driven Dosing Pump - 0.2% to 2% (500:1 - 50:1) Dosage Rate - Manual On/Off & Viton Seals - 1 to 22 GPM- 1-Inch MPT
$733.73
MSRP: $880.47
Margin: 20%

Qty: 4

Commerce, CA: 1

Sacramento, CA: 3

0
STK

PRODUCT IN STOCK

WMR020
MixRite TF10 Water-Driven Dosing Pump - 0.2% to 2% (500:1 - 50:1) Dosage Rate - 2 to 45 GPM - 1-1/2-Inch MPT
$1,050.07
MSRP: $1,260.09
Margin: 20%

Qty: 0
0
O
OUT OF STOCK
WMR030
MixRite TF10 Water-Driven Dosing Pump - 0.1% to 1% (1000:1 - 100:1) Dosage Rate - Chlorine & PPA Compatible - 2 to 45 GPM- 1-1/2-Inch MPT
$1,107.34
MSRP: $1,328.80
Margin: 20%

Qty: 1

Commerce, CA: 1

Sacramento, CA: 0

0
STK

PRODUCT IN STOCK

Details

MixRite Water Driven Injectors are water powered proportioning pumps that need no electricity and accurately dispenses at different water pressure and water flows. Ideal for in-line injection of fertilizers and additives for crop production or simply adjusting pH.  Mixrite products are manufactured in an ISO certified facility and are ISO 9001 2008 certified.

Available in several models with a wide variety of injection rates, and different materials to withstand many types of aggressive acids, alkaline, and solvents.

The 500 series is available as a CW model with seals and components for mildly aggressive additives, 1400 models for corrosive material, acid, alkaline, solvent, and a PVDF model for the most aggressive additives.

We understand that everyone is not an expert in irrigation.  If you need assistance understanding our Mixrite dosing pumps and determining which product is correct for your installation please give us a call.  Our Arable Acres technical sales representatives are available for product selection, design, quotations, and post sale support.  Products cost money, consultation is free.

WHICH MIXRITE SERIES IS RIGHT FOR ME?

Series 1 (1 m3/h) High Flow Rate

  • Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
  • Flow rate: 529 to 2645 GPH (20 to 10,000 LPH)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 3/4-Inch

Series 2.5 (2.5 m3/h) Low Flow Rate

  • Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
  • Flow rate: 185 to 660 GPH (7 to 2500 LPH)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 3/4-Inch

Series 3.5 (3.5 m3/h) Low Flow Rate

  • Water pressuer: 2.9 to 120 PSI (0.2 to 8 bar)
  • Flow rate: 265 to 930 GPH (10 to 3500 LPH)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 3/4-Inch

Series TF-5 (5 m3/h) Low Flow Rate

  • Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
  • Flow rate: 0.2 to 22 GPH (0.05 to 5 m3/h)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 1-Inch (32 mm)

Series TF-10 (10 m3/h) Low Flow Rate

  • Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
  • Flow rate: 0.2 to 45 GPH (0.05 to 10 m3/h)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 1-1/2-Inch (50 mm)

Series TF-25 (25 m3/h) Low Flow Rate

  • Water pressuer: 14.7 to 120 PSI (1 to 8 bar)
  • Flow rate: 9 to 110 GPH (0.2 to 25 m3/h)
  • Working temperature: 39.2 to 104 Degrees F (4 to 40 Degrees C)
  • Connection: 2-Inch (63 mm)

COMMON MIXRITE DOSING PUMPS

Model No.

Flow Rate

Induction Rates

Induction %

Oz/Gal

mL/Gal

Chemical Shut-Off

569*

.5 – 11 GPM (3.4 – 41.6 LPM)

1000:1 to 111:1

.1% to .9%

.128 – 1.15

3.84 – 34.5

Yes

570*

.5  – 11 GPM (3.4 – 41.6 LPM)

333:1 to 50:1

.3% to 2%

.4 – 2.56

12 – 76.8

No

571*

.5 – 11 GPM (3.4 – 41.6 LPM)

333:1 to 50:1

.3% to 2%

.4 – 2.56

12 – 76.8

Yes

572

.5 – 11 GPM (3.4 – 41.6 LPM)

250:1 to 25:1

.4% to 4%

.5 – 5.12

15 – 153.6

Yes

573*

.5 – 11 GPM (3.4 – 41.6 LPM)

250:1 to 25:1

.4% to 4%

.5 – 5.12

15 – 153.6

Yes

577IN

.5 – 11 GPM (3.4 – 41.6 LPM)

333:1 to 50:1

.3% to 2%

.4 – 2.56

12 – 76.8

Yes

579IN

.5  – 11 GPM (3.4 – 41.6 LPM)

250:1 to 25:1

.3% to 4%

.4 – 5.12

15 – 153.6

Yes

1400A or M

.5 – 14 GPM (.5 – 53 LPM)

200:1 to 500:1

.05% to .2%

.04 – .25

1.2 – 7.5

M Model

1401A or M

.5 – 14 GPM (.5 – 53 LPM)

1000:1 to 111:14

.1% to .9%

.128 – 1.15

3.84 – 34.5

M Model

1402A or M

.5 – 14 GPM (.5 – 53 LPM)

333:1 to 50:1

.3% to 2%

.4 – 2.56

12 – 76.8

M Model

1405A or M

.5 – 14 GPM (.5 – 53 LPM)

100:1 – 20:1

.5% to 5%

.64 – 6.4

19.2 – 192

M Model

1410A or M

.5 – 14 GPM (.5 – 53 LPM)

100:1 – 10:1

1% to 10%

1.28 – 12.8

38.4 – 384

M Model

 

OPERATING PRINCIPLE

  • The pilot operating valve samples the pressure level at multiple points, and controls the opening condition of the diaphragm.
  •  This operation governs the flow rates to generate a stable 1:10 ratio between lines.

CASE STUDY

  • Total water flow rate: 67.3 m3/h
  • Desired dosage rate:  0.1%
  • Additive amount: 67.3 x 0.1% = 0.0673 m3/h
  • Relevant configuration:  4’’, 1.5"
  • Main line water flow: 67.3 x 0.9 = 60.57 m3/h
  • By-Pass water flow: 67.3 x 0.1 = 6.73 m3/h
  • Relevant injector:  TF10 0.2%-2%
  • Dosage setting on injector: 0.0673 / 6.73 = 1%

FEATURES & BENEFITS

  • Keeps constant proportional flow rate
  • Hydraulic, volumetric, and non-electric
  • Dosing proportional to flowrate
  • Precision: surface quality optimized with no waste
  • Flow rate between main line and sub-main line will remain 10:1 at wide flow rates
  • Working pressure up to 8 bar (116 PSI)
  • High UV resistance
  • High chemical resistance
  • Supplied pre - set. No need for calibration
  • Excellent dosing repeatability and homogeneity
  • Easy to install, operate and maintain, with no electricity risk
CA Prop. 65 Warning WARNING: This product may expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.